CS25 MOLD AND MOISTURE RESISTANCE CEILING (EASY FRAME)

CS25 Mold and Moisture Resistance Ceiling (Easy Frame)

Introduction

This ceiling system developed for a room that requires Mold and Moisture Resistance performance. Based on International Standard ASTM G-21 (Grade 0).

Suitable to be applied at:

  • Laboratory
  • Hospital
  • Bathroom
  • Any other area that requires Mold Resistance performance. 

Supporting Material:

  • Frame: JayaBMS Hanger System (Bracket PN 220/221, Clip Adjuster PN 222, Rod PN 227 M4), JayaBMS Top Cross Rail PN 250, JayaBMS Batten PN-251, Wall Angle PN-252
  • Board: 1 Layer of Jayaboard Wet-Area Optimum 9mm
  • Jointing: JayaCompound as Jayaboard Recommendation.

Use Hitung Material fiture to help you figure total materials needed.

Specification:

  • Weight: 6.5 Kg/m2

Notes:

  • All the materials above calculated based on a room with a size of (10x10m). Another room sizes should be considered further.
  • Suspension gap max. of 1000mm
  • Primary frames gap max. of 1000mm
  • Secondary frames gap max. of 600mm
  • All the materials above needs to be reconfirmed by the Contractor / Applicators regarding bookings material inquiry order.
  • Exclude waste material.

 

Information provided are for reference purpose only and due care has been taken to ensure accuracy at time of publication. Products, specifications and requirements may vary according to geographical locations and applications. As each project is unique, please contact your local Jayaboard representative for further assessment.